IT-Zertifizierung EMC E20-885

IT-Zertifizierung EMC E20-885

Access Routing and LAN Switching;Advanced Routing and Switching;APE;APE for Validating Knowledge;Architecture;
CCDA;CCDE; CCDP;CCENT;CCIE;CCIE Data Center;CCIP; CCNA;
CCNA Security;CCNA Wireless;CCNA Voice;CCNP;CCNP Data Center
;CCNP Service Provider; CCNP Wireless;CCNP Security;CCNP SP Operations; CCNP Voice;CCSP;CCVP;Cisco Express Foundation Field Specialist;Cisco Security Sales Specialist;Cisco Specialist;Cisco Virtual Classroom;Connected Grid;Content Networking;Data-Center;Field Technician;IP Communications;IronPort; Network Management; Optical;Others
;Proctored Exams for Validating Knowledge;Sales Expert; Security Specialist;Service Provider Video;SMB;SP Video
;Storage Networking; Substation Automation;TelePresence Video
;Unified Communications;VPN and Security; WAASSE; Wireless LAN

E20-885 VNX Solutions Expert Exam for Implementation Engineers Der einfachste Weg für die IT-Prüfung vorzubereiten, ist die Praxis-Tests auf Zertifizierungsprüfung Muster zu nehmen und zu verstehen, die richtige sowie falsche Antwort Erklärungen Deine Zweifel klären. Lesen Sie dazu auch relevante technische Artikel zu versierter in der damit verbundenen Technologie.

IT-Zertifizierung EMC E20-885

QUESTION NO: 1
A customer wants to replicate a CIFS environment from a legacy EMC Celerra to a new EMCVNX. Users are able to access CIFS shares from both arrays. The CIFS shares are on different networks and replication is not running. The customer wants to make sure there will be no network restrictions preventing replication between the data movers on two different networks.
What TCP ports should they ask the network team to open?

A. 8888, 8887, 5081
B. 80, 443, 8080
C. 5057, 445, 5087
D. 23, 25, 22

Answer: A

QUESTION NO: 2
A customer recently upgraded from vSphere v4.x to vSphere v5.0 to benefit from new VMFS-5 features for their existing ‘DataStore1’ and ‘DataStore2’ datastores on an EMC VNX. A second identically configured VNX was implemented and the customer created two additional datastores on the new VNX.
After monitoring the environment, the customer notices the VMs on ‘ DataStore1 ’ and ‘ DataStore2 ’ are not using the same sub-block structure as the two new datastores.
What is the reason for this behavior?

A. The old VMs are on an upgraded VMFS-5 datastore.
B. The old VMs are still running old VMware tools.
C. The new VMFS-5 features need to be licensed and activated.
D. The new VMFS-5 cannot support two VNX storage systems.

Answer: A

QUESTION NO: 3
A storage administrator reports they are unable configure SAN Copy connections between two VNX. The required cabling is in place and zoning is correct, but the SP connections still do not appear in Unisphere Manager. What could have caused this issue?

A. SAN Copy is not installed on both VNX arrays.
B. SAN Copy is only licensed for local copies.
C. The SP ports are already being used by hosts.
D. Both VNX arrays are not in the same domain.

Answer: D

QUESTION NO: 4
A Pool used for FAST VP has the following configuration:
Flash drives: 1,000 GB, with 1,000 GB free
SAS drives: 5,000 GB, with 2,500 GB free
NL-SAS drives: 20,000 GB, with 11,500 GB free
The tiering policy is set to Auto. An additional 600 GB of new data is written to the Pool.
What is the data distribution after the data is written?

A. Flash drives: 960 GB free SAS drives: 2,400 GB free NL-SAS drives: 11,040 GB free
B. Flash drives: 400 GB free SAS drives: 2,500 GB free NL-SAS drives: 11,500 GB free
C. Flash drives: 900 GB free SAS drives: 2,000 GB free NL-SAS drives: 11,500 GB free
D. Flash drives: 970 GB free SAS drives: 2,350 GB free NL-SAS drives: 11,080GB free

Answer: A

IT-Zertifizierung EMC E20-885

Hinterlasse eine Antwort